Home > Products > Core Equipment > Filling Line
Tunnel - Sterilization & Depyrogenation Tunnel Series


The tunnel is designed to sterilize and depyrogenise vials by a laminar flow of hot air with continuous process. Grade A is assured in all tunnel areas above the openings of the vials. Vials are transported through the preheating zone, heating zone and cooling zone by a conveyor belt made of stainless steel wire mesh.

 

Key Features

  • Scientific calculation, modular design and Independent air duct design.
  • Negative pressure sealing for the HEPA in the heating zone.
  • Double cooling zone to prevent thermal shock.
  • Flexible pressure zone concept for safe processes.
  • Validation ports for filter integrity test, particle counting and air velocity.
  • Power failure protection: backup power supply switch / compressed air cooling in the heating zone.
  • Different working modes.
  • Critical parameters of the process are continuously monitored and printed.
  • Automatic gate between different zones(option)
  • Automatic tight gate for cooling zone(option)
  • Discharge device for the end process(option)
  • Sterilize the cooling zone by heat(option)